Argeton System Used on Aluminium Substructure with Verticle 'T' Rails
   

Aluminium brackets are fixed with approved fasteners along the horizontal axis of the support wall, spaced as structurally necessary. In this regard, attention must be paid to the design of fixed and floating points according to BS 8118:Part 1: 1991

Vertical aluminium ‘T’ section support profiles are inserted into the brackets (a special receiver jaw enables exact adjustment). Once the support profile is aligned it is fixed with blind rivets or screws. The best results are achieved if the 'T' sections are pre-punched to the tile grid.

The Argeton tiles are mounted on the substructure free of tension using self-tapping stainless steel screws or aluminium hollow rivets, and held in place at four points with proprietary clips. Tiling of the façade is undertaken from the bottom of the panel upwards.